Skip to content

Factory reset

The factory reset returns Wi-Fi, settings and history to the state in which the device was delivered. Afterwards you set the device up again as you did the first time.

Cloud pairing

If the device is connected to the cloud during the factory reset, it reports the reset there and is removed from your WattWächter account. If it was offline, it stays in the account — remove it in the cloud portal: Removing the device. Details under In the cloud.

Triggering a factory reset

With the function button

  1. Press and hold the function button.
  2. After 2 seconds the LED turns solid red. If you let go now, nothing happens.
  3. After 7 seconds the LED goes off — the factory reset is done.
  4. Release the button. The device restarts.

Where the button is: see LED and function button.

By unplugging and replugging quickly (last resort)

Only use this route if you cannot reach the function button or it does not respond. The device also resets itself if it restarts five times in a row and runs for less than 15 seconds each time — for example if you pull the plug and plug it back in five times in quick succession. Restarts caused by a too-low supply voltage do not count. The same data is deleted as when pressing the function button — only the cloud is not told, because the device is not yet connected that early in the start.

Not via the web interface, app or API

A factory reset cannot be triggered from the web interface or the REST API. They only offer a restart, which keeps all data (see Settings → System).

What is deleted

Area After the factory reset
Wi-Fi Both Wi-Fi profiles deleted, including the static IP address
Access point "Always on" off, custom name and password deleted
MQTT Switched off; broker, user and password deleted; client ID and topic prefix back to default (WattWaechter/wattwaechter-<MAC>) — if the device was set up before firmware 1.3, the topic prefix changes
Modbus TCP Switched off, port back to 502
API security API authentication off, new READ and WRITE tokens generated — the old ones no longer work
Cloud Pairing on the device deleted, data transfer to the cloud off (see In the cloud)
Device Device name, status LED (back on), language (German), time zone and NTP server back to default
Automatic updates Switched on again (default)
Tariffs All tariffs stored on the device deleted
Switch devices All switching rules deleted
Gas/water meter Medium, meter reading, volume per revolution, sensitivity or minimum swing, calorific value and z-number deleted or back to default; likewise the previous meter reading entries, the counted reading and the learned coil assignment
History 15-minute values and daily values on the device deleted
Log file Deleted
Custom CA certificate Deleted (see MQTT → TLS)

Afterwards the device is as it left the factory. Only the installed firmware including the web interface and the device certificate the device uses to identify itself to the cloud are kept.

In the cloud

If the device is connected to the cloud during the factory reset (reset with the button), it reports the reset there:

  • The device is removed from your WattWächter account, its settings in the cloud are deleted.
  • The tariffs of this device in the cloud are deleted right away.
  • The factory reset does not delete the readings already transferred. They stay assigned to your account: if you pair the device with the same account again later, history, name and address are back (the tariffs are not). You can only delete the history once the device is paired again — if you want it gone, remove the device before the factory reset with Disconnect and delete cloud data, see Removing the device.
  • Tenant accesses stay. Remove them in the cloud portal if needed.

If the device was offline — or you reset it by unplugging and replugging —, the cloud does not learn about it. The device then stays in your account; remove it in the cloud portal under Removing the device. If you pair it with your account again instead, it gets its tariffs back from the cloud.

Set up the meter again

After the factory reset the WattWächter Gas knows neither the medium nor the meter reading. Set both again after the Wi-Fi setup — see Setup → Set the medium.

After the factory reset

The device starts without Wi-Fi credentials. It then opens its own access point (WattWaechter-GW-XXXXXX) and starts Bluetooth mode (LED pulses blue).

Set it up again: Setup → Set up Wi-Fi

If you had switched on API authentication, it is now off again and the device has new READ and WRITE tokens. Switch it on again if you need it and enter the new tokens wherever you used the old ones (e.g. Home Assistant, Loxone, scripts). For the cloud you need a new pairing token — see Cloud Portal → Pair a device.