Supported meters¶
The WattWächter Gas comes in two variants: Magnetic Field (GW-MF) and Inductive (GW-ID). They differ only in the sensor — setup, operation and features are the same. Which variant you need depends on what turns inside the register of your gas meter. This page explains the two variants, shows how to recognise your meter and lists common meters.
Magnetic Field or Inductive?¶
-
Magnetic Field (GW-MF)
A small magnet sits in the last digit wheel of the register. On every revolution it passes the sensor; the sensor measures the change in the magnetic field — one revolution is one count.
This is the case with most diaphragm gas meters.
-
Inductive (GW-ID)
Instead of a magnet, a disc with a metal marker turns inside the register, the so-called Cyble target. The sensor detects the marker as it passes. The disc is often hidden inside the register — so not seeing it does not mean your meter does not fit.
On gas meters this design is less common than the magnet — you find it e.g. on the Itron/Pipersberg G4 RF1 c.
The magnet and the metal marker sit inside the register and cannot be seen from outside. How you can still tell which variant fits is shown in the next section.
Which variant fits?¶
Hints on the dial¶
The label on the dial often tells you which variant fits. It is a good indication, but no guarantee:
- If it shows a pulse value such as "1 imp ≙ 0,01 m³", the register usually has a magnet — that points to Magnetic Field.
- If it shows "1 trc ≙ 0,01 m³" or the type name contains a small "c" (e.g. G4 RF1 c), this indicates a metal marker — that points to Inductive.
- If it says "ENCODER" without a pulse value, or the meter shows the reading on a display instead of number wheels, it most likely cannot be read with either variant.
The spot below the register¶
The spot below the register — where the sensor will sit — gives a second hint:
-
Recess below the register → Magnetic Field
A recess for a pulse sensor, often with a label such as "1 Imp = 0.01 m³" nearby. Many meters with a magnet have no such recess — they fit Magnetic Field too if the dial shows a pulse value.
-
Round mount below the window → Inductive
A round mount for a sensor, e.g. on the Itron/Pipersberg G4 RF1 c or Pipersberg BK-G4 Ac/AcT. Then Inductive fits.
How the sensor is fixed to your meter is shown in Meter preparation → Mounting the adapter.
Not sure? Send us a photo
Don't know which variant fits? Send a photo of your meter to support@wattwaechter.com — ideally one where the register and the area below it are clearly visible. We will tell you which variant you need before you order.
Example meters¶
The following lists show common gas meters and the variant that fits them. They are not complete. What counts is your meter: look for the hints on the dial — or, if in doubt, send us a photo at support@wattwaechter.com.
Magnetic Field (GW-MF)¶
| Manufacturer | Model | Note | Mounting |
|---|---|---|---|
| Elster / Honeywell | BK-G1.6, BK-G2.5 with a mechanical register | Universal adapter (glued) | |
| Elster / Honeywell | BK-G4 to BK-G25 with a mechanical register, e.g. BK-G4, BK-G4T, BK-G4 MT | also sold as Kromschröder (older names e.g. BK 4, BK 6) | BK adapter |
| Pipersberg | BK-G2.5 | identical to Elster BK | Universal adapter (glued) |
| Pipersberg | BK-G4T, BK-G6 and larger | identical to Elster BK | BK adapter |
| Apator (Metrix) | UG G1.6, UG G2.5, UG G4, 2UG G4, 2UG G6, also T/TK | also sold as Pipersberg | Universal adapter (glued) |
| Apator (Metrix) | UG G10, UG G16, UG G25 | pulse value often 0.1 m³ — enter it as volume per revolution during setup | Universal adapter (glued) |
| Metrix | G4 (older models, e.g. 6G4L) | Universal adapter (glued) | |
| Pietro Fiorentini | RS/2001, RS/2.0, RST/2.0, RS/2,4 (G4–G6) | Universal adapter (screwed) | |
| Pietro Fiorentini | MM (G10–G25) | Universal adapter (glued) | |
| SamGas | G4, G6 | meters made by Pietro Fiorentini | Universal adapter (screwed) |
| Heitland (HL) | HL G4 | e.g. at EnBW; meter made by Pietro Fiorentini | Universal adapter (screwed) |
| Itron / Schlumberger / Actaris / Pipersberg | G4 RF1 (without "c") | pulse value often 0.1 m³ — enter it as volume per revolution during setup. A dedicated adapter is in development. | Universal adapter (glued) |
| Itron / Schlumberger / Actaris | Gallus 2000 | Universal adapter (glued) | |
| Itron | ACD G10, ACD G16, G25, G40 (without "c") | Universal adapter (glued) | |
| GMT | BK-G4 | BK adapter | |
| GMT | GT4 | Universal adapter (glued) | |
| AEM | GN G4T | with the label "1 imp = 0,01 m³". We have not tested it with "1 imp = 0,004 m³" yet — if you have such a meter and want to find out with us, get in touch. | Universal adapter (glued) |
Inductive (GW-ID)¶
| Manufacturer | Model | Note | Mounting |
|---|---|---|---|
| Itron / Pipersberg | G4 RF1 c | label "1 trc ≙ 0,01 m³", round window below the register | Itron adapter |
| Pipersberg | BK-G4 Ac, BK-G4 AcT (also "BK-Gaszähler BK-G4 AcT") | red-and-white disc in a round window below the register | Itron adapter |
| Itron | Gallus c, ACD G10 c, ACD G16 c, G25 c, G40 c | Universal adapter (glued) |
Cannot be read with either variant¶
| Manufacturer | Model | How to recognise it |
|---|---|---|
| Elster / Honeywell | BK-G… A and BK-G… AT, e.g. BK-G4 AT, BK-G6 AT | dial says "ENCODER", no pulse value |
| Pietro Fiorentini | RSE | display instead of number wheels |
| Itron | RF1 e, ACD e | display instead of number wheels |