Meter preparation¶
For electricity meters
This guide applies to every WattWächter for electricity: Plus, Tasmota (Gen.1 and Gen.2), USB and TTL.
Before you set up your WattWächter, take care of three things at the meter: Wi-Fi, power and an unlocked meter.
1. Wi-Fi at the meter¶
The WattWächter Plus and the WattWächter Tasmota in Wi-Fi mode need a 2.4 GHz Wi-Fi at the meter — they cannot see 5 GHz networks. Meter cabinets are often in the basement, and a metal door weakens Wi-Fi a lot, so check with your phone right at the meter, with the door closed, whether your Wi-Fi reaches it. If the signal is weak, a Wi-Fi repeater nearby helps.
This does not apply to the WattWächter Tasmota in USB mode, the WattWächter USB and the WattWächter TTL — they pass the data on by cable.
2. Power at the meter¶
The WattWächter Plus and the WattWächter Tasmota are powered via USB-C. Plan for a USB-C power supply (5 V, at least 500 mA) at a socket near the meter — or a free USB-C port. In USB mode the connected computer or Raspberry Pi powers the Tasmota as well; it then has to be within cable reach of the meter. The WattWächter USB is powered by the computer it is plugged into. The WattWächter TTL is powered by your own hardware.
3. Unlock the meter¶
For the WattWächter to capture all meter data completely, many electricity meters must first be unlocked. Without unlocking, most meters only provide a limited data set.
Why is unlocking necessary?¶
For privacy reasons, modern digital electricity meters are configured by default to only output a minimal data set via the optical interface. To access the extended data set (e.g., current power, detailed consumption values), the meter must be unlocked with a PIN.
Request PIN from your network operator
You can obtain the PIN from your network operator (not your electricity provider!). Usually, a short email or phone call is sufficient. The PIN is free of charge and is typically provided within a few days.
You can find your network operator on your electricity bill or on the meter itself.
Unlocking the meter with a flashlight¶
The meter is operated via its optical button – a light sensor that you shine a flashlight on. On some meters this is a separate field next to the display, but on many the sensor sits directly behind the optical data interface. In that case, remove the WattWächter or reading head first.
The animation shows the complete procedure: enter the PIN, turn on info mode, disable PIN protection. Enter your own PIN in the “Your PIN” field and it shows exactly the light pulses you need to give.
Key points:
InF Onenables the extended data set. Without it, the meter usually sends only meter readings, no current power.Pin OFFdisables the PIN prompt permanently, so the values don't lock again after a few minutes.- Short light pulse = count up or page on, 3–5 seconds of continuous light = toggle a setting.
- Pulsed too early? Wait until the display returns to its default view, then start over.
- The order of menu items, wait times and how long to shine vary by manufacturer. If in doubt, check your meter's manual or ask your network operator.
Careful at HIS CLr
While paging, HIS CLr usually comes before InF. Only page on with a short pulse there – do not shine continuously, or the meter's consumption history will be deleted.
Procedure as text
- Shine light on the optical button briefly once. The meter runs a display test, then the PIN entry appears with
0in the first position. - For each digit, give as many short light pulses as the digit requires (none for a
0), then wait about 3 seconds. The meter accepts the digit and moves to the next one. - After the last digit the meter is unlocked and shows additional values such as current power.
- Page on with short light pulses until
InF OFF(before it you usually see2.8.0, the values of the last 1, 7, 30 and 365 days, andHIS CLr). - At
InF OFF, shine continuously for 3–5 seconds untilInF Onappears. - One short light pulse takes you to
Pin On. Shine again for 3–5 seconds untilPin OFFappears.
Both settings are stored permanently.
After unlocking¶
After successful unlocking, the meter provides the extended data set. The WattWächter can now read all available values:
- Current power (Watts)
- Meter reading consumption (kWh)
- Meter reading feed-in (kWh) — if available
- Additional detailed values depending on the meter model
You can tell the unlocking was successful when the WattWächter dashboard shows the current power and not just the meter readings.
Available data varies
Which data your meter provides depends on the configuration by the manufacturer or network operator. Some meters only provide basic data (meter reading, power), while others include additional values like voltage, current, or phase power. This configuration cannot be changed by the end user. Meters that never transmit instantaneous power are marked with ¹ in the Supported Meters overview.
Special case: NES/Echelon meters¶
Meters from NES/Echelon work differently from the SML and OBIS meters described here: they do not send data on their own, they only answer when asked — and they only release their data after a log-on with a password. There is no PIN entry via the optical button on these meters.
You get this password from your metering point operator. Request it before setting up the device — without the password the readings stay empty.
WattWächter Plus only
This meter type is currently supported by the WattWächter Plus only, from firmware 1.2.1. It detects the meter by itself; you then enter the password in the web interface — see Settings → Meter.
How to request the password, enter it and narrow down errors is explained on Reading NES Meters (ANSI C12.18).