Readings¶
From the counted revolutions the WattWächter Gas calculates these values:
- the meter reading in m³ — as shown on your meter,
- the current flow rate in m³/h,
- the current power in kW — the flow rate, converted with the same factor,
- the energy in kWh — using the calorific value and Z-number from your gas bill (see below).
From cubic metres to kilowatt hours¶
Your gas meter measures the volume in cubic metres. Gas is billed in kilowatt hours, though. The supplier converts with two values that appear on every gas bill:
| Value | Meaning | Also shown on the bill as | Typical range |
|---|---|---|---|
| Calorific value | Energy content of the gas in kWh per m³ | "Hs", "billing calorific value" | 10 to 12 kWh/m³ |
| Z-number | Correction for pressure and temperature at the meter | "Zustandszahl" | 0.9 to 1.0 |
The calculation is:
Energy (kWh) = volume (m³) × Z-number × calorific value (kWh/m³)
Example: 100 m³ × 0.95 × 11.0 kWh/m³ = 1,045 kWh.
The same factor turns the flow rate into power:
Power (kW) = flow rate (m³/h) × Z-number × calorific value (kWh/m³)
Example: 0.42 m³/h × 0.95 × 11.0 kWh/m³ ≈ 4.39 kW.
Both values are on your gas bill, usually where the consumption is converted from m³ to kWh. Enter them during setup in the web interface (Settings → Gas/water meter, fields Calorific value and Z-number). Without an entry the device uses 11.0 kWh/m³ and 0.95.
New values with every gas bill
The calorific value and Z-number change from one bill to the next. The device therefore always stores m³ and converts to kWh only for display. If you enter the values from the new bill on a tariff, they apply to its period — earlier periods keep being calculated with their own values.
OBIS codes¶
In the REST API, in MQTT and in the cloud, gas values appear with these codes:
| OBIS Code | Description | Unit |
|---|---|---|
7-0:3.0.0 |
Meter reading (volume) | m³ |
7-0:43.0.0 |
Flow rate | m³/h |
7-0:16.7.0 |
Power (calculated from flow rate, calorific value and Z-number) | kW |
Full notation
For electricity the WattWächter uses the short form (e.g. 1.8.0). Gas always appears in full notation (7-0:3.0.0), because the short form could be confused with electricity codes. The leading 7 stands for gas.