Skip to content

OpenDTU-OnBattery

OpenDTU-OnBattery controls your inverter by the power at the grid connection — for example for zero export with the Dynamic Power Limiter. It reads that power directly from the WattWächter Tasmota: over HTTP through the Tasmota interface, without an MQTT broker and without an extra meter in the distribution board.

OpenDTU or OpenDTU-OnBattery?

The original OpenDTU only reads the inverter and has no input for a power meter. This guide is for the fork OpenDTU-OnBattery.

In short

URL http://192.168.178.50/cm?cmnd=status%2010 (your WattWächter's IP address)
JSON path StatusSNS/<meter name>/<power field> — e.g. StatusSNS/eHZ/Power; both names are in your meter script
Unit W
Sign positive = import, negative = export — what OpenDTU-OnBattery expects, do not change the sign

Prerequisites

  • The WattWächter Tasmota is set up, connected to your Wi-Fi and shows the current power in its web interface. This applies to the Gen.2 and to the Gen.1 in Wi-Fi mode.
  • Your meter script contains a line for the current power (OBIS 16.7.0). Some meters do not send this value — OpenDTU-OnBattery cannot regulate with them.
  • OpenDTU-OnBattery and the WattWächter are in the same network, and the WattWächter has a fixed IP address in the router (DHCP reservation).
  • Deep Sleep is off: a sleeping WattWächter does not answer requests.

The endpoint

The Tasmota command Status 10 returns all meter values as JSON. Over HTTP you call it like this — the space becomes %20 in the URL:

curl -s "http://192.168.178.50/cm?cmnd=status%2010"
{
  "StatusSNS": {
    "Time": "2026-10-07T21:57:29",
    "eHZ": {
      "E_in": 12345.678,
      "E_out": 42.123,
      "Power": -812
    }
  }
}

Open the URL in a browser once to see the names your script assigns.

Working out the JSON path

The path has three parts, separated by slashes:

StatusSNS/eHZ/Power
Part Where from?
StatusSNS always the same
Meter name (eHZ) sixth field of the script line that starts with +1,
Power field (Power) fourth field after the @ in the line for the current power

Using the script for the EMH eHZ as an example (excerpt):

>M 1
+1,3,s,0,9600,eHZ
1,77070100010800ff@1000,Bezug,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,Aktuelle Leistung,W,Power,0

Here the meter is called eHZ and the current power Power. Most scripts call the field Power, some meters use a different name (e.g. Power_cur) — what counts is what your script and the response above show.


Setting up OpenDTU-OnBattery

  1. In OpenDTU-OnBattery open Settings → Power Meter and switch on Enable Power Meter.
  2. Choose HTTP(S) + JSON as the Power Meter Type.
  3. Enter the values from the table.
  4. Check your entries under Test Configuration with Send HTTP(S) request(s) and process response(s) — OpenDTU-OnBattery then shows the power it read.
  5. Save. The power then appears in the live view.
Field Entry
Polling Interval 2 seconds
Individual HTTP(S) requests per value off
URL (value 1) http://192.168.178.50/cm?cmnd=status%2010
Authorization Type None — with a Tasmota web password: Basic, username admin
Timeout 1000 milliseconds
JSON Path StatusSNS/eHZ/Power (adapt to your script)
Unit W
Change Sign off

Value 2 and value 3 stay disabled: the current power already is the sum of all phases.

After that, set up the Dynamic Power Limiter in OpenDTU-OnBattery — it uses the power meter as its control value.


Troubleshooting

“Unable to access JSON key …”

The JSON path does not match the response. Open the URL in a browser and compare meter name and power field character by character — upper and lower case matter.

The response contains no power

Your meter does not send the current power, or the extended data output has not been unlocked yet — see Preparing the meter. If the line is missing entirely from the script for your meter, the meter does not provide the value.

No connection or timeout
  • Has the WattWächter been given a new IP address? Set a DHCP reservation in the router.
  • Does the URL contain %20 instead of a space?
  • Is Deep Sleep active?
HTTP 401

A web password is set in Tasmota. Set the Authorization Type to Basic and enter the username admin and the password.

The inverter regulates in the wrong direction