Release Notes¶
v15.6.0¶
- No more getting stuck during updates (WattWächter Wi-Fi/USB Gen.2): If the reader can't reach Wi-Fi during an update, it returns to the previous firmware on its own after 5 minutes
- Visible update mode (WattWächter Wi-Fi/USB Gen.2): The LED slowly pulses magenta while in update mode. A short button press leaves update mode and starts the regular firmware
- LED can be switched off (WattWächter Wi-Fi/USB Gen.2): New command
WWLed 0turns the status LED off,WWLed 1turns it back on. To keep the setting after a restart, add=>WWLed 0to the>Bsection of the script. Update and reset indications are still shown - USB console stays available (WattWächter Wi-Fi/USB Gen.2): Fixed – the USB console stopped responding as soon as the meter was read via the IR reader
- Readable raw data (WattWächter Wi-Fi/USB Gen.2): USB passthrough mode (
sensor53 p) now shows data from ASCII-protocol meters (7E1) as plain text - More robust MQTT: Hardened MQTT library and fixed TLS certificate handling for ECDSA keys
v15.5.0¶
- Major platform update (WattWächter Tasmota Gen.2): New ESP-IDF v5.5.4 / Arduino Core v3.3.8 – latest base and long-term update capability
- Reliable encrypted MQTT: Fixed – crash when an MQTT-TLS connection failed
- Fixed WiFi access point: New
BSSidcommand binds the reader to a specific access point – more stable connection in environments with multiple APs or repeaters - Console convenience: Backspace correction while typing in the console
Changed access security
The HTTP referer check is now enabled by default (SetOption128). If you read meter data or send commands via external HTTP, you may need to set SetOption128 1.
v15.4.0¶
- Updated foundation (WattWächter Tasmota Gen.2): New ESP-IDF v5.5 generation – more modern WiFi/Bluetooth stacks and security updates as the base
- Stable long-term operation (WattWächter Tasmota Gen.1): Fixed – memory leak and crash when the router supplies the time-server (NTP) address via DHCP
- No crash on WiFi-off: The
Wifi 0command no longer triggers a reboot - Clean HTTP data output: Correct responses to HTTP/1.0 requests – no more stray characters when reading meter values
v15.3.0¶
- CRC check: Automatic validation of SML telegrams with auto-detection of the algorithm
- MQTT only after valid data: No more zero values after reboot
- 64-bit OBIS fix: Correct handling of large meter readings (Long64)
- IRAM optimization: Saves scarce IRAM on ESP8285
- Longer strings: Variables up to 255 characters (previously 48)
- Local variables: Better script modularization
-
FNN decoder (
@##): Meter number in plain text instead of hexDecoder Example output @#1454414732303234323535353531@##1 SAG20 2425 5551Example script line:
1,77070100600100ff@##,Meter Number,,Meter_ID,0
v14.4.1 – Initial Release¶
First stable firmware version for the WattWächter Tasmota.